diff options
-rw-r--r-- | Source/SPServerSupport.h | 8 | ||||
-rw-r--r-- | Source/SPServerSupport.m | 5 | ||||
-rw-r--r-- | Source/SPTableStructureDelegate.m | 25 |
3 files changed, 27 insertions, 11 deletions
diff --git a/Source/SPServerSupport.h b/Source/SPServerSupport.h index 4cb68726..6f6f4038 100644 --- a/Source/SPServerSupport.h +++ b/Source/SPServerSupport.h @@ -88,6 +88,9 @@ // Indexes BOOL supportsIndexKeyBlockSize; + // Data types + BOOL supportsFractionalSeconds; + // Server versions NSInteger serverMajorVersion; NSInteger serverMinorVersion; @@ -239,6 +242,11 @@ */ @property (readonly) BOOL supportsQuotingEngineTypeInCreateSyntax; +/** + * @property supportsFractionalSeconds Indicates whether the server supports fractional seconds in date/time data types. + */ +@property (readonly) BOOL supportsFractionalSeconds; + - (id)initWithMajorVersion:(NSInteger)majorVersion minor:(NSInteger)minorVersion release:(NSInteger)releaseVersion; - (void)evaluate; diff --git a/Source/SPServerSupport.m b/Source/SPServerSupport.m index 78a2b287..95120494 100644 --- a/Source/SPServerSupport.m +++ b/Source/SPServerSupport.m @@ -73,6 +73,7 @@ @synthesize supportsTriggers; @synthesize supportsIndexKeyBlockSize; @synthesize supportsQuotingEngineTypeInCreateSyntax; +@synthesize supportsFractionalSeconds; @synthesize serverMajorVersion; @synthesize serverMinorVersion; @synthesize serverReleaseVersion; @@ -192,6 +193,9 @@ // MySQL 4.0 doesn't seem to like having the ENGINE/TYPE quoted in a table's create syntax supportsQuotingEngineTypeInCreateSyntax = [self isEqualToOrGreaterThanMajorVersion:4 minor:1 release:0]; + + // Fractional second support wasn't added until MySQL 5.6.4 + supportsFractionalSeconds = [self isEqualToOrGreaterThanMajorVersion:5 minor:6 release:4]; } /** @@ -280,6 +284,7 @@ supportsTriggers = NO; supportsIndexKeyBlockSize = NO; supportsQuotingEngineTypeInCreateSyntax = NO; + supportsFractionalSeconds = NO; } /** diff --git a/Source/SPTableStructureDelegate.m b/Source/SPTableStructureDelegate.m index c2bdb98c..ec6e984f 100644 --- a/Source/SPTableStructureDelegate.m +++ b/Source/SPTableStructureDelegate.m @@ -548,37 +548,37 @@ [aCell setEnabled:NO]; } else { - // validate cell against current field type + // Validate cell against current field type + NSString *rowType = @""; NSDictionary *theRow = NSArrayObjectAtIndex(tableFields, rowIndex); - NSString *theRowType = @""; - if ((theRowType = [theRow objectForKey:@"type"])) { - theRowType = [[theRowType stringByTrimmingCharactersInSet:[NSCharacterSet whitespaceAndNewlineCharacterSet]] uppercaseString]; + if ((rowType = [theRow objectForKey:@"type"])) { + rowType = [[rowType stringByTrimmingCharactersInSet:[NSCharacterSet whitespaceAndNewlineCharacterSet]] uppercaseString]; } // Only string fields allow encoding settings if (([[aTableColumn identifier] isEqualToString:@"encoding"])) { - [aCell setEnabled:([fieldValidation isFieldTypeString:theRowType] && [[tableDocumentInstance serverSupport] supportsPost41CharacterSetHandling])]; + [aCell setEnabled:([fieldValidation isFieldTypeString:rowType] && [[tableDocumentInstance serverSupport] supportsPost41CharacterSetHandling])]; } // Only string fields allow collation settings and string field is not set to BINARY since BINARY sets the collation to *_bin else if ([[aTableColumn identifier] isEqualToString:@"collation"]) { - [aCell setEnabled:([fieldValidation isFieldTypeString:theRowType] && [[theRow objectForKey:@"binary"] integerValue] == 0 && [[tableDocumentInstance serverSupport] supportsPost41CharacterSetHandling])]; + [aCell setEnabled:([fieldValidation isFieldTypeString:rowType] && [[theRow objectForKey:@"binary"] integerValue] == 0 && [[tableDocumentInstance serverSupport] supportsPost41CharacterSetHandling])]; } // Check if UNSIGNED and ZEROFILL is allowed else if ([[aTableColumn identifier] isEqualToString:@"zerofill"] || [[aTableColumn identifier] isEqualToString:@"unsigned"]) { - [aCell setEnabled:([fieldValidation isFieldTypeNumeric:theRowType] && ![theRowType isEqualToString:@"BIT"])]; + [aCell setEnabled:([fieldValidation isFieldTypeNumeric:rowType] && ![rowType isEqualToString:@"BIT"])]; } // Check if BINARY is allowed else if ([[aTableColumn identifier] isEqualToString:@"binary"]) { - [aCell setEnabled:([fieldValidation isFieldTypeAllowBinary:theRowType])]; + [aCell setEnabled:([fieldValidation isFieldTypeAllowBinary:rowType])]; } // TEXT, BLOB, and GEOMETRY fields don't allow a DEFAULT else if ([[aTableColumn identifier] isEqualToString:@"default"]) { - [aCell setEnabled:([theRowType hasSuffix:@"TEXT"] || [theRowType hasSuffix:@"BLOB"] || [fieldValidation isFieldTypeGeometry:theRowType]) ? NO : YES]; + [aCell setEnabled:([rowType hasSuffix:@"TEXT"] || [rowType hasSuffix:@"BLOB"] || [fieldValidation isFieldTypeGeometry:rowType]) ? NO : YES]; } // Check allow NULL @@ -588,11 +588,14 @@ // TEXT, BLOB, date, and GEOMETRY fields don't allow a length else if ([[aTableColumn identifier] isEqualToString:@"length"]) { - [aCell setEnabled:([theRowType hasSuffix:@"TEXT"] || [theRowType hasSuffix:@"BLOB"] || ([fieldValidation isFieldTypeDate:theRowType] && ![theRowType isEqualToString:@"YEAR"]) || [fieldValidation isFieldTypeGeometry:theRowType]) ? NO : YES]; + [aCell setEnabled:([rowType hasSuffix:@"TEXT"] || + [rowType hasSuffix:@"BLOB"] || + ([fieldValidation isFieldTypeDate:rowType] && ![[tableDocumentInstance serverSupport] supportsFractionalSeconds] && ![rowType isEqualToString:@"YEAR"]) || + [fieldValidation isFieldTypeGeometry:rowType]) ? NO : YES]; } else { [aCell setEnabled:YES]; - } + } } } |