Commit message (Collapse) | Author | Age | Files | Lines | |
---|---|---|---|---|---|
* | Update asterisk_log.php | nagyrobi | 2013-09-19 | 1 | -5/+11 |
| | |||||
* | Update lcdproc.xml | Tony | 2013-09-18 | 1 | -0/+1 |
| | | | - Small bug (forgot <option>) | ||||
* | Merge pull request #474 from timdufrane/master | Renato Botelho | 2013-09-18 | 1 | -3/+3 |
|\ | | | | | Fix Incorrect Directory Replacement | ||||
| * | Contentscanners preg_replace | timdufrane | 2013-08-16 | 1 | -1/+1 |
| | | | | | | This condition also applies to the contentscanner section, and there is no variable substitution going on. Does not affect installs that use /usr/local, and allows the correct behavior on installs in /usr/pbi/dansguardian/... or wherever else (as long as DANSGUARDIAN_DIR is the correct directory). | ||||
| * | Fix Incorrect Directory Replacement | timdufrane | 2013-08-13 | 1 | -2/+2 |
| | | | | | | | | On some installs, the directory ends up being /usr/pbi/dansguardian-xxx/... This results in include lines not being written correctly and broken config files. DANSGUARDIAN_DIR should be present on every system. | ||||
* | | Merge pull request #486 from voyagertm/patch-2 | Renato Botelho | 2013-09-18 | 1 | -3/+19 |
|\ \ | | | | | | | Update lcdproc.inc | ||||
| * | | Update lcdproc.inc | voyagertm | 2013-09-16 | 1 | -3/+19 |
| | | | | | | | | | | | | - Added the extra USB COM port from lcdproc.xml - Changed the HD44780 part to fit the lcdproc.xml and other changes | ||||
* | | | Merge pull request #485 from voyagertm/patch-1 | Renato Botelho | 2013-09-18 | 1 | -3/+87 |
|\ \ \ | | | | | | | | | Update lcdproc.xml | ||||
| * | | | Update lcdproc.xml | voyagertm | 2013-09-16 | 1 | -3/+87 |
| |/ / | | | | | | | | | | | | | - Changed the version - Added an extra USB COM port someone needed - Added option for the HD44780 driver | ||||
* / / | squid3-dev - external acl helper for captive portal authentication integration. | Marcello Coutinho | 2013-09-18 | 1 | -0/+85 |
|/ / | |||||
* | | bandwidthd - whitespace formatting | Phil Davis | 2013-09-14 | 1 | -24/+24 |
| | | |||||
* | | bandwidthd - whitespace formatting | Phil Davis | 2013-09-14 | 1 | -5/+5 |
| | | |||||
* | | bandwidthd - specify explicitly the graph location index.html | Phil Davis | 2013-09-12 | 1 | -1/+1 |
| | | | | | | | | This helps some people whose browser does not find index.html automagically, and does not harm anything for others. http://forum.pfsense.org/index.php/topic,49165.msg362705.html#msg362705 | ||||
* | | Add some dummy XML files for CLI-only packages since the package system ↵ | jim-p | 2013-09-11 | 4 | -0/+176 |
| | | | | | | | | likes to have them there. | ||||
* | | bandwidthd version bump | Phil Davis | 2013-09-09 | 1 | -1/+1 |
| | | |||||
* | | bandwidthd - check for interface subnet also specified by user | Phil Davis | 2013-09-09 | 1 | -5/+14 |
| | | | | | | | | | | Check for the case where a user specifies the interface subnet to listen on in the "subnet" box, which is actually not required. In this case, do not put the subnet into the config twice. It fixes a GUI data entry confusion that is reported from time to time in the forum, e.g. http://forum.pfsense.org/index.php/topic,49165.msg320801.html#msg320801 http://forum.pfsense.org/index.php/topic,66354.0.html | ||||
* | | old code looked for 2.0 to decide if this was 2+, changed to 2. | Anthony Paul | 2013-09-05 | 1 | -3/+11 |
| | | | | | | | | made sure some dirs were created and permissions set before trying to write to them | ||||
* | | fix typo | Chris Buechler | 2013-09-04 | 2 | -3/+3 |
| | | |||||
* | | Add a manual config validation option to HAproxy (using -c to only check ↵ | jim-p | 2013-08-29 | 3 | -1/+21 |
| | | | | | | | | config file) | ||||
* | | Fixup service matching so that OpenVPN and CP instances aren't missing after ↵ | jim-p | 2013-08-29 | 3 | -2/+46 |
| | | | | | | | | one was added. | ||||
* | | Don't try to (re)start services during boot. | jim-p | 2013-08-28 | 2 | -1/+8 |
| | | |||||
* | | Teach blinkled how to write an rcfile since it claims to use one in its ↵ | jim-p | 2013-08-28 | 2 | -4/+35 |
| | | | | | | | | service definition. | ||||
* | | Fixup a bunch of package service descriptions. | jim-p | 2013-08-28 | 25 | -23/+25 |
| | | |||||
* | | Service Watchdog: If the description is empty, try to fetch the package ↵ | jim-p | 2013-08-28 | 2 | -3/+5 |
| | | | | | | | | description instead. Also, don't offer cron in the list of services to monitor. Don't show blank/empty services. Bump version. | ||||
* | | Switch to rw before doing disk write operations when syncing sudoers file. | jim-p | 2013-08-28 | 2 | -1/+4 |
| | | |||||
* | | Use a better function to get the service status. | jim-p | 2013-08-28 | 2 | -2/+2 |
| | | |||||
* | | Rename to avoid potential confusion with existing utility. | jim-p | 2013-08-28 | 7 | -91/+91 |
| | | |||||
* | | Add ProcWatch, a little package to monitor services and restart them if they ↵ | jim-p | 2013-08-27 | 5 | -0/+443 |
| | | | | | | | | are stopped. Needs more testing, but the basics work. | ||||
* | | Rather use transparent here | Warren Baker | 2013-08-27 | 1 | -1/+1 |
| | | |||||
* | | Fix config syntax problem | Warren Baker | 2013-08-27 | 1 | -1/+1 |
| | | |||||
* | | Make sure reverse entries are correctly added so that DNS Rebinding does not ↵ | Warren Baker | 2013-08-27 | 1 | -8/+10 |
| | | | | | | | | block reverse DNS records | ||||
* | | Make backend is added correctly, if a single or multiple ones are specified. | Warren Baker | 2013-08-27 | 1 | -20/+24 |
| | | |||||
* | | Some more cleanups | Warren Baker | 2013-08-27 | 1 | -5/+5 |
| | | |||||
* | | General code syntax cleanup | Warren Baker | 2013-08-27 | 1 | -174/+149 |
| | | |||||
* | | Use OpenVPN Manager client management port if specified for the server concerned | Phil Davis | 2013-08-25 | 1 | -2/+7 |
| | | | | | | | | | | | | If the OpenVPN server has the client management port field specified, then use that port number when generating the OpenVPN Manager client config file, otherwise use the default of "166". See: forum.pfsense.org/index.php/topic,63668.0.html Discussion: https://github.com/jochenwierum/openvpn-manager/issues/17 Related pull request on pfsense repo: https://github.com/pfsense/pfsense/pull/783 | ||||
* | | Merge pull request #478 from PiBa-NL/HAProxy-devel-defaultbackend | Jim P | 2013-08-25 | 1 | -1/+1 |
|\ \ | | | | | | | HAProxy-devel, fix (again) default backend selection | ||||
| * | | fix (again) default backend selection | PiBa-NL | 2013-08-25 | 1 | -1/+1 |
| | | | |||||
* | | | Merge pull request #476 from overhacked/fix-siproxd-rtpenable | Renato Botelho | 2013-08-21 | 2 | -5/+13 |
|\ \ \ | | | | | | | | | siproxd: separate enable/disable of RTP proxy from rest of daemon | ||||
| * | | | siproxd: changed rtpenable to true by default | Ross Williams | 2013-08-21 | 2 | -2/+2 |
| | | | | | | | | | | | | | | | | Per rbgarga's recommendation | ||||
| * | | | siproxd: separate enable/disable of RTP proxy from rest of daemon | Ross Williams | 2013-08-17 | 2 | -3/+21 |
| | | | | |||||
| * | | | Allowing siproxd to run even if RTP proxy is disabled | Ross Williams | 2013-08-16 | 1 | -13/+3 |
| | | | | |||||
* | | | | nut: Adding cyberpower MIB as a selectable value | Moritz Heiber | 2013-08-21 | 1 | -0/+4 |
| | | | | | | | | | | | | | | | | | | | | Enable the 'cyberpower' MIB to be able to use the snmp-ups driver together with pfsense's nut package | ||||
* | | | | HAproxy config parameter clitimeout is deprecated, should now be "timeout ↵ | jim-p | 2013-08-20 | 1 | -1/+1 |
| | | | | | | | | | | | | | | | | client". | ||||
* | | | | Add the most common values as default in system patches for path strip, ↵ | jim-p | 2013-08-16 | 2 | -1/+5 |
| | | | | | | | | | | | | | | | | base, and whitespace. Also bump version. | ||||
* | | | | chaged text in description of "output PostgreSQL" to link | Individual IT Services | 2013-08-15 | 1 | -1/+1 |
| | | | | |||||
* | | | | For NRPE2, honor the "sudo" checkbox if it's checked and sudo exists on the ↵ | jim-p | 2013-08-14 | 2 | -2/+6 |
| | | | | | | | | | | | | | | | | system. Also, only add -w and -c if the boxes are filled in. Fixes #3145 | ||||
* | | | | Merge pull request #473 from individual-it/master | Jim P | 2013-08-14 | 3 | -3/+69 |
|\ \ \ \ | |_|_|/ |/| | | | added posibility to use external postgreSQL database to store results of bandwidthd | ||||
| * | | | corrected typo for log_error | Individual IT Services | 2013-08-14 | 1 | -1/+1 |
| | | | | |||||
| * | | | deleted empty rows | Individual IT Services | 2013-08-14 | 1 | -1/+0 |
| | | | | |||||
| * | | | added link to the Documentation about Zabbix User Parameters | Individual IT Services | 2013-08-14 | 1 | -2/+3 |
| | | | |