authorBill Marquette <bill.marquette@gmail.com>2009-02-06 19:18:00 -0600
committerBill Marquette <bill.marquette@gmail.com>2009-02-06 19:18:00 -0600
commit55eddd7accf2c5f9b0f52b22a010c4c4b7c130d1 (patch)
treeba4783bab1dd65f1ceef2dfac9fdbd515531d18b /config/nut
parent67780cc9d469288742aea5bc378c29a54edd5ec5 (diff)
downloadpfsense-packages-55eddd7accf2c5f9b0f52b22a010c4c4b7c130d1.tar.gz
pfsense-packages-55eddd7accf2c5f9b0f52b22a010c4c4b7c130d1.tar.bz2
pfsense-packages-55eddd7accf2c5f9b0f52b22a010c4c4b7c130d1.zip
mv packages to config dir to match web layout
Diffstat (limited to 'config/nut')
-rw-r--r--config/nut/nut.inc394
-rw-r--r--config/nut/nut.xml518
-rw-r--r--config/nut/status_nut.php242
3 files changed, 1154 insertions, 0 deletions
diff --git a/config/nut/nut.inc b/config/nut/nut.inc
new file mode 100644
index 00000000..a8465dce
--- /dev/null
+++ b/config/nut/nut.inc
@@ -0,0 +1,394 @@
+<?php
+/*
+ nut.inc
+ part of pfSense (http://www.pfsense.com/)
+
+ Copyright (C) 2007 Ryan Wagoner <rswagoner@gmail.com>.
+ All rights reserved.
+
+ Redistribution and use in source and binary forms, with or without
+ modification, are permitted provided that the following conditions are met:
+
+ 1. Redistributions of source code must retain the above copyright notice,
+ this list of conditions and the following disclaimer.
+
+ 2. Redistributions in binary form must reproduce the above copyright
+ notice, this list of conditions and the following disclaimer in the
+ documentation and/or other materials provided with the distribution.
+
+ THIS SOFTWARE IS PROVIDED ``AS IS'' AND ANY EXPRESS OR IMPLIED WARRANTIES,
+ INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY
+ AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE
+ AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY,
+ OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
+ SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
+ INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
+ CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
+ ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
+ POSSIBILITY OF SUCH DAMAGE.
+*/
+
+ require_once("config.inc");
+ require_once("functions.inc");
+
+ /* Nut */
+
+ define('NUT_RCFILE', '/usr/local/etc/rc.d/nut.sh');
+ define('NUT_DIR','/usr/local/etc/nut');
+
+ function nut_notice ($msg) { syslog(LOG_NOTICE, "nut: {$msg}"); return; }
+ function nut_warn ($msg) { syslog(LOG_WARNING, "nut: {$msg}"); return; }
+
+ function nut_action ($action) {
+ if (file_exists(NUT_RCFILE))
+ mwexec(NUT_RCFILE.' '.$action);
+ }
+
+ function nut_config ($name) {
+ global $config;
+ if($config['installedpackages']['nut']['config'][0]["{$name}"])
+ return $config['installedpackages']['nut']['config'][0]["{$name}"];
+ return null;
+ }
+
+ function nut_config_sub ($name,$len) {
+ global $config;
+ if(nut_config($name))
+ return substr(nut_config($name),0,strlen(nut_config($name))-$len);
+ return null;
+ }
+
+ function nut_write_config($file, $text, $mask = null, $uid = null) {
+ $conf = fopen($file, "w");
+ if(!$conf) {
+ nut_warn("Could not open {$file} for writing.");
+ exit;
+ }
+ fwrite($conf, $text);
+ fclose($conf);
+ if($mask) chmod($file, $mask);
+ if($uid) chown($file, $uid);
+ }
+
+ function nut_validate_ip($ip,$check_cdir) {
+ /* validate cdir */
+ if($check_cdir) {
+ $ip_array = explode("/",$ip);
+ if(count($ip_array) == 2) {
+ if($ip_array[1] < 1 || $ip_array[1] > 32)
+ return false;
+ } else
+ if(count($ip_array) != 1)
+ return false;
+ } else
+ $ip_array[] = $ip;
+
+ /* validate ip */
+ if(!eregi("^[0-9]{1,3}\.[0-9]{1,3}\.[0-9]{1,3}\.[0-9]{1,3}$", $ip_array[0]))
+ return false;
+ foreach(explode(".", $ip_array[0]) as $sub)
+ if($sub < 0 || $sub > 256)
+ return false;
+ return true;
+ }
+
+ function before_form_nut($pkg) {
+ /* return available serial ports */
+ $handle = popen('dmesg | grep \'^sio[0-9]: type\'','r');
+ $read = fread($handle, 2096);
+ pclose($handle);
+
+ /* explode at the newlines */
+ $read = explode("\n",$read);
+
+ /* parse resulting text */
+ foreach($read as $line) {
+ if($line!= '') {
+ $names[] = 'ttyd'.$line{3}.' (COM'.($line{3}+1).')';
+ $values[] = '/dev/ttyd'.$line{3};
+ }
+ }
+
+ /* find correct field */
+ $i = 0;
+ foreach ($pkg['fields']['field'] as $field) {
+ if ($field['fieldname'] == 'port')
+ break;
+ $i++;
+ }
+ $field = &$pkg['fields']['field'][$i];
+
+ /* add available serial ports */
+ for ($i = 0; $i < count($values) ; $i++)
+ $field['options']['option'][] = array('name' => $names[$i], 'value' => $values[$i]);
+ }
+
+ function validate_form_nut($post, $input_errors) {
+ global $config;
+
+ /* monitor remote validation */
+ if($post['monitor'] == 'remote') {
+ if(!$post['remotename'])
+ $input_errors[] = 'You must specify a name in the \'Remote UPS Name\' field';
+ if($post['remotename'] && !eregi('^[a-z0-9_.-]+$', $post['remotename']))
+ $input_errors[] = 'Only [Aa-Zz], [0-9], and [-_] accepted in the \'Remote UPS Name\' field';
+ if(!$post['remoteaddr'] || !nut_validate_ip($post['remoteaddr'],false))
+ $input_errors[] = 'You must specify a valid address \'Remote UPS Address\' field';
+ if(!$post['remoteuser'])
+ $input_errors[] = 'You must specify a name in the \'Remote UPS User\' field';
+ if(!$post['remotepass'])
+ $input_errors[] = 'You must specify a name in the \'Remote UPS Password\' field';
+ }
+
+ /* monitor local validation */
+ elseif($post['monitor'] == 'local') {
+ if(!$post['name'])
+ $input_errors[] = 'You must specify a name in the \'Local UPS Name\' field';
+ if($post['name'] && !eregi('^[a-z0-9_.-]+$', $post['name']))
+ $input_errors[] = 'Only [Aa-Zz], [0-9], and [-_] accepted in the \'Local UPS Name\' field';
+ if(!$post['driver'])
+ $input_errors[] = 'You must select a driver in the \'Local UPS Driver\' field';
+ if(!$post['port'])
+ $input_errors[] = 'You must select a port in the \'Local UPS Port\' field';
+ if($post['allowaddr'] && !nut_validate_ip($post['allowaddr'],true))
+ $input_errors[] = 'You must specify a valid address \'Local Remote Access Address\' field';
+ }
+ }
+
+ function deinstall_package_nut() {
+ nut_action('stop');
+
+ @unlink(NUT_RCFILE);
+ @unlink(NUT_DIR.'/upsmon.conf');
+ @unlink(NUT_DIR.'/ups.conf');
+ @unlink(NUT_DIR.'/upsd.conf');
+ @unlink(NUT_DIR.'/upsd.users');
+
+ exec('rm -rf /var/db/nut');
+ }
+
+ function sync_package_nut_remote() {
+ $remotename = nut_config('remotename');
+ $remoteaddr = nut_config('remoteaddr');
+ $remoteuser = nut_config('remoteuser');
+ $remotepass = nut_config('remotepass');
+
+ if(!($remotename && $remoteaddr && $remoteuser && $remotepass))
+ return false;
+
+ /* upsmon.conf */
+ $upsmon_conf = <<<EOD
+MONITOR {$remotename}@{$remoteaddr} 1 {$remoteuser} {$remotepass} slave
+MINSUPPLIES 1
+SHUTDOWNCMD "/sbin/shutdown -h +0"
+POWERDOWNFLAG /etc/killpower
+EOD;
+
+ $stop = <<<EOD
+if [ `pgrep upsmon | wc -l` != 0 ]; then
+ /usr/bin/killall upsmon
+ while [ `pgrep upsmon | wc -l` != 0 ]; do
+ sleep 1
+ done
+ fi
+EOD;
+
+ $start = $stop."\n\t/usr/local/sbin/upsmon {$remotename}@{$remoteaddr}\n";
+
+ /* write out configuration */
+ conf_mount_rw();
+ nut_write_config(NUT_DIR.'/upsmon.conf', $upsmon_conf, 0640, 'uucp');
+ write_rcfile(array(
+ 'file' => 'nut.sh',
+ 'start' => $start,
+ 'stop' => $stop
+ )
+ );
+ conf_mount_ro();
+
+ return true;
+ }
+
+ function sync_package_nut_local() {
+ $name = nut_config('name');
+ $driver = nut_config_sub('driver', 2);
+ $port = nut_config('port');
+ $upstype = nut_config_sub('upstype', 3);
+ $cable = nut_config_sub('cable', 3);
+ $allowaddr = nut_config('allowaddr');
+ $allowuser = nut_config('allowuser');
+ $allowpass = nut_config('allowpass');
+
+ if(!($name && $driver && $port))
+ return false;
+
+ /* some installs are missing the lock dir */
+ if(!is_dir('/var/spool/lock')) {
+ @mkdir('/var/spool');
+ mkdir('/var/spool/lock');
+ chown('/var/spool/lock', 'uucp');
+ chgrp('/var/spool/lock', 'dialer');
+ }
+
+ /* determine permissions for port */
+ if($port != 'auto') {
+ $port_rel = "chown root {$port}";
+ $port_set = "chown uucp {$port}";
+ }
+
+ /* ups.conf */
+ /* for usb ups run as root */
+ if($port == 'auto') {
+ $ups_conf = "user=root\n";
+ $ovr_user = '-u root';
+ }
+ $ups_conf .= "[{$name}]\n";
+ $ups_conf .= "driver={$driver}\n";
+ $ups_conf .= "port={$port}\n";
+ if($cable)
+ $ups_conf .= "cable={$cable}\n";
+ if($upstype)
+ $ups_conf .= "upstype={$upstype}\n";
+
+ /* upsd.conf */
+ $upsd_conf = "ACL all 0.0.0.0/0\n";
+ $upsd_conf .= "ACL localhost 127.0.0.1/32\n";
+ if($allowaddr && $allowuser) {
+ $upsd_conf .= "ACL remote {$allowaddr}\n";
+ $upsd_conf .= "ACCEPT remote\n";
+ }
+ $upsd_conf .= "ACCEPT localhost\n";
+ $upsd_conf .= "REJECT all\n";
+
+ /* upsd.users */
+ $upsd_users = "[monuser]\n";
+ $upsd_users .= "password = mypass\n";
+ $upsd_users .= "allowfrom = localhost\n";
+ $upsd_users .= "upsmon master\n";
+ if($allowaddr && $allowuser) {
+ $upsd_users .= "\n[$allowuser]\n";
+ $upsd_users .= "password = $allowpass\n";
+ $upsd_users .= "allowfrom = remote\n";
+ $upsd_users .= "upsmon master\n";
+ }
+
+ /* upsmon.conf */
+ $upsmon_conf = <<<EOD
+MONITOR {$name}@localhost 1 monuser mypass master
+MINSUPPLIES 1
+SHUTDOWNCMD "/sbin/shutdown -h +0"
+POWERDOWNFLAG /etc/killpower
+EOD;
+
+ $stop = <<<EOD
+ if [ `pgrep upsmon | wc -l` != 0 ]; then
+ echo stopping upsmon
+ /usr/bin/killall upsmon
+ while [ `pgrep upsmon | wc -l` != 0 ]; do
+ sleep 1
+ done
+ fi
+ if [ `pgrep upsd | wc -l` != 0 ]; then
+ echo stopping upsd
+ /usr/bin/killall upsd
+ fi
+ if [ `pgrep {$driver} | wc -l` != 0 ]; then
+ echo stopping {$driver}
+ /usr/local/libexec/nut/upsdrvctl stop
+ fi
+ sleep 1
+ if [ `pgrep {$driver} | wc -l` != 0 ]; then
+ echo forcing {$driver} termination
+ /usr/bin/killall {$driver}
+ while [ `pgrep {$driver} | wc -l` != 0 ]; do
+ sleep 1
+ done
+ fi
+ {$port_rel}
+EOD;
+
+ $start = <<<EOD
+if [ `pgrep {$driver} | wc -l` != 0 ]; then
+ {$stop}
+ fi
+ {$port_set}
+ echo starting {$driver}
+ if /usr/local/libexec/nut/upsdrvctl start; then
+ echo starting upsd
+ /usr/local/sbin/upsd {$ovr_user}
+ echo starting upsmon
+ /usr/local/sbin/upsmon {$name}@localhost
+ else
+ echo {$driver} failed to start
+ fi
+EOD;
+
+ /* write out configuration */
+ conf_mount_rw();
+ nut_write_config(NUT_DIR.'/ups.conf', $ups_conf);
+ nut_write_config(NUT_DIR.'/upsd.conf', $upsd_conf, 0640, 'uucp');
+ nut_write_config(NUT_DIR.'/upsd.users', $upsd_users, 0640, 'uucp');
+ nut_write_config(NUT_DIR.'/upsmon.conf', $upsmon_conf, 0640, 'uucp');
+ write_rcfile(array(
+ 'file' => 'nut.sh',
+ 'start' => $start,
+ 'stop' => $stop
+ )
+ );
+ conf_mount_ro();
+
+ return true;
+ }
+
+ function sync_package_nut() {
+ global $config;
+ global $input_errors;
+
+ config_lock();
+
+ nut_action('stop');
+
+ /* create state path */
+ if(!is_dir('/var/db/nut')) {
+ mkdir('/var/db/nut');
+ chmod('/var/db/nut', 0700);
+ chown('/var/db/nut', 'uucp');
+ }
+
+ if(nut_config('monitor') == 'remote')
+ $return = sync_package_nut_remote();
+ elseif(nut_config('monitor') == 'local')
+ $return = sync_package_nut_local();
+
+ if($return && $_POST['monitor']) {
+ /* only start if changing settings as we have a startup script for system boot */
+ /* this prevents service from starting / stopping / starting on boot */
+
+ nut_notice('Starting service');
+ nut_action('start');
+ if((int)exec('pgrep upsmon | wc -l') == 0)
+ nut_notice('Service failed to start: check configuration');
+
+ } elseif(!$return && file_exists(NUT_RCFILE)) {
+ /* no parameters user does not want nut running */
+ /* lets stop the service and remove the rc file */
+
+ if(!nut_config('monitor'))
+ nut_notice('Service stopped: nut disabled');
+ else
+ nut_notice('Service stopped: check configuration');
+
+ conf_mount_rw();
+ unlink(NUT_RCFILE);
+ unlink(NUT_DIR.'/upsmon.conf');
+ /* might not always exist */
+ @unlink(NUT_DIR.'/ups.conf');
+ @unlink(NUT_DIR.'/upsd.conf');
+ @unlink(NUT_DIR.'/upsd.users');
+ exec('rm -rf /var/db/nut');
+ conf_mount_ro();
+ }
+
+ config_unlock();
+ }
+?>
diff --git a/config/nut/nut.xml b/config/nut/nut.xml
new file mode 100644
index 00000000..fdaa6295
--- /dev/null
+++ b/config/nut/nut.xml
@@ -0,0 +1,518 @@
+<?xml version="1.0" encoding="utf-8" ?>
+<!DOCTYPE packagegui SYSTEM "../schema/packages.dtd">
+<?xml-stylesheet type="text/xsl" href="../xsl/package.xsl"?>
+<packagegui>
+ <copyright>
+ <![CDATA[
+/* $Id$ */
+/* ========================================================================== */
+/*
+ authng.xml
+ part of pfSense (http://www.pfSense.com)
+ Copyright (C) 2007 to whom it may belong
+ All rights reserved.
+
+ Based on m0n0wall (http://m0n0.ch/wall)
+ Copyright (C) 2003-2006 Manuel Kasper <mk@neon1.net>.
+ All rights reserved.
+ */
+/* ========================================================================== */
+/*
+ Redistribution and use in source and binary forms, with or without
+ modification, are permitted provided that the following conditions are met:
+
+ 1. Redistributions of source code must retain the above copyright notice,
+ this list of conditions and the following disclaimer.
+
+ 2. Redistributions in binary form must reproduce the above copyright
+ notice, this list of conditions and the following disclaimer in the
+ documentation and/or other materials provided with the distribution.
+
+ THIS SOFTWARE IS PROVIDED ``AS IS'' AND ANY EXPRESS OR IMPLIED WARRANTIES,
+ INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY
+ AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE
+ AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY,
+ OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
+ SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
+ INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
+ CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
+ ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
+ POSSIBILITY OF SUCH DAMAGE.
+ */
+/* ========================================================================== */
+ ]]>
+ </copyright>
+ <description>Describe your package here</description>
+ <requirements>Describe your package requirements here</requirements>
+ <faq>Currently there are no FAQ items provided.</faq>
+ <name>nut</name>
+ <version>2.0.4</version>
+ <title>Services: NUT</title>
+ <savetext>Change</savetext>
+ <aftersaveredirect>/status_nut.php</aftersaveredirect>
+ <include_file>/usr/local/pkg/nut.inc</include_file>
+ <menu>
+ <name>NUT</name>
+ <tooltiptext>Set Network UPS Tools settings.</tooltiptext>
+ <section>Services</section>
+ <url>/status_nut.php</url>
+ </menu>
+ <service>
+ <name>nut</name>
+ <rcfile>nut.sh</rcfile>
+ <executable>upsmon</executable>
+ </service>
+ <tabs>
+ <tab>
+ <text>NUT Status</text>
+ <url>/status_nut.php</url>
+ </tab>
+ <tab>
+ <text>NUT Settings</text>
+ <url>/pkg_edit.php?xml=nut.xml&amp;id=0</url>
+ <active/>
+ </tab>
+ </tabs>
+ <additional_files_needed>
+ <prefix>/usr/local/pkg/</prefix>
+ <chmod>0755</chmod>
+ <item>http://www.pfsense.com/packages/config/nut/nut.inc</item>
+ </additional_files_needed>
+ <additional_files_needed>
+ <prefix>/usr/local/www/</prefix>
+ <chmod>0755</chmod>
+ <item>http://www.pfsense.com/packages/config/nut/status_nut.php</item>
+ </additional_files_needed>
+ <fields>
+ <field>
+ <fielddescr>UPS Monitoring</fielddescr>
+ <fieldname>monitor</fieldname>
+ <type>select</type>
+ <required/>
+ <options>
+ <option>
+ <name>Disabled</name>
+ <value></value>
+ </option>
+ <option>
+ <name>Local UPS</name>
+ <value>local</value>
+ </option>
+ <option>
+ <name>Remote UPS</name>
+ <value>remote</value>
+ </option>
+ </options>
+ </field>
+ <field>
+ <fielddescr>&lt;strong&gt;Local UPS Name&lt;/strong&gt;</fielddescr>
+ <fieldname>name</fieldname>
+ <type>input</type>
+ </field>
+ <field>
+ <fielddescr>&lt;strong&gt;Local UPS Model&lt;/strong&gt;</fielddescr>
+ <fieldname>driver</fieldname>
+ <description>If generic or cable specified in parenthesis you need
+ to select the appropriate option below.</description>
+ <type>select</type>
+ <options>
+ <option>
+ <name>APC Back-UPS (Generic)</name>
+ <value>genericups00</value>
+ </option>
+ <option>
+ <name>APC Back-UPS RS (Generic)</name>
+ <value>genericups01</value>
+ </option>
+ <option>
+ <name>APC Back-UPS Pro (Cable)</name>
+ <value>apcsmart00</value>
+ </option>
+ <option>
+ <name>APC Smart-UPS (Cable)</name>
+ <value>apcsmart01</value>
+ </option>
+ <option>
+ <name>APC Matrix-UPS</name>
+ <value>apcsmart02</value>
+ </option>
+ <option>
+ <name>APC Masterswitch (Generic)</name>
+ <value>genericups02</value>
+ </option>
+ <option>
+ <name>APC Back-UPS USB</name>
+ <value>newhidups00</value>
+ </option>
+ <option>
+ <name>APC Back-UPS LS USB</name>
+ <value>newhidups01</value>
+ </option>
+ <option>
+ <name>APC Back-UPS ES USB</name>
+ <value>newhidups02</value>
+ </option>
+ <option>
+ <name>APC Back-UPS RS USB</name>
+ <value>newhidups03</value>
+ </option>
+ <option>
+ <name>APC Back-UPS Pro USB</name>
+ <value>newhidups04</value>
+ </option>
+ <option>
+ <name>APC Smart-UPS USB</name>
+ <value>newhidups05</value>
+ </option>
+ <option>
+ <name>Belkin Regulator Pro</name>
+ <value>belkin00</value>
+ </option>
+ <option>
+ <name>Belkin Universal UPS</name>
+ <value>belkinunv00</value>
+ </option>
+ <option>
+ <name>Belkin Universal UPS USB</name>
+ <value>newhidups06</value>
+ </option>
+ <option>
+ <name>Best Power Fortress</name>
+ <value>bestups00</value>
+ </option>
+ <option>
+ <name>Best Power Fortress Telecom</name>
+ <value>bestups01</value>
+ </option>
+ <option>
+ <name>Best Power Axxium Rackmount</name>
+ <value>bestups02</value>
+ </option>
+ <option>
+ <name>Best Power Patriot Pro</name>
+ <value>bestups03</value>
+ </option>
+ <option>
+ <name>Best Power Patriot (Generic/Cable)</name>
+ <value>genericups03</value>
+ </option>
+ <option>
+ <name>Best Power Micro-Ferrups</name>
+ <value>bestuferrups00</value>
+ </option>
+ <option>
+ <name>Best Power Fortress/Ferrups</name>
+ <value>bestfcom00</value>
+ </option>
+ <option>
+ <name>Cyber Power Systems 320AVR</name>
+ <value>cyberpower00</value>
+ </option>
+ <option>
+ <name>Cyber Power Systems 500AVR</name>
+ <value>cyberpower01</value>
+ </option>
+ <option>
+ <name>Cyber Power Systems 650AVR</name>
+ <value>cyberpower02</value>
+ </option>
+ <option>
+ <name>Cyber Power Systems 700AVR</name>
+ <value>cyberpower03</value>
+ </option>
+ <option>
+ <name>Cyber Power Systems 800AVR</name>
+ <value>cyberpower04</value>
+ </option>
+ <option>
+ <name>Cyber Power Systems 850AVR</name>
+ <value>cyberpower05</value>
+ </option>
+ <option>
+ <name>Cyber Power Systems 900AVR</name>
+ <value>cyberpower06</value>
+ </option>
+ <option>
+ <name>Cyber Power Systems 1250AVR</name>
+ <value>cyberpower07</value>
+ </option>
+ <option>
+ <name>Cyber Power Systems 1500AVR</name>
+ <value>cyberpower08</value>
+ </option>
+ <option>
+ <name>Inform GUARD Line Interactive</name>
+ <value>powercom00</value>
+ </option>
+ <option>
+ <name>Meta System HF Line</name>
+ <value>metasys00</value>
+ </option>
+ <option>
+ <name>Meta System HF Millennium</name>
+ <value>metasys01</value>
+ </option>
+ <option>
+ <name>Meta System HF TOP Line</name>
+ <value>metasys02</value>
+ </option>
+ <option>
+ <name>Meta System ECO Network</name>
+ <value>metasys03</value>
+ </option>
+ <option>
+ <name>Meta System ECO</name>
+ <value>metasys04</value>
+ </option>
+ <option>
+ <name>Meta System ally HF</name>
+ <value>metasys05</value>
+ </option>
+ <option>
+ <name>Meta System Megaline</name>
+ <value>metasys06</value>
+ </option>
+ <option>
+ <name>MGE UPS SYSTEMS NOVA AVR</name>
+ <value>mge-shut00</value>
+ </option>
+ <option>
+ <name>MGE UPS SYSTEMS Pulsar Ellipse</name>
+ <value>mge-shut01</value>
+ </option>
+ <option>
+ <name>MGE UPS SYSTEMS Ellipse Office</name>
+ <value>mge-shut02</value>
+ </option>
+ <option>
+ <name>MGE UPS SYSTEMS Pulsar EXtreme</name>
+ <value>mge-shut03</value>
+ </option>
+ <option>
+ <name>MGE UPS SYSTEMS Comet</name>
+ <value>mge-shut04</value>
+ </option>
+ <option>
+ <name>MGE UPS SYSTEMS Pulsar Esprit</name>
+ <value>mge-shut05</value>
+ </option>
+ <option>
+ <name>MGE UPS SYSTEMS Evolution</name>
+ <value>mge-shut06</value>
+ </option>
+ <option>
+ <name>MGE UPS SYSTEMS Comet USB</name>
+ <value>newhidups07</value>
+ </option>
+ <option>
+ <name>MGE UPS SYSTEMS Protection Center USB</name>
+ <value>newhidups08</value>
+ </option>
+ <option>
+ <name>MGE UPS SYSTEMS NOVA AVR USB</name>
+ <value>newhidups09</value>
+ </option>
+ <option>
+ <name>MGE UPS SYSTEMS Pulsar Ellipse USB</name>
+ <value>newhidups10</value>
+ </option>
+ <option>
+ <name>MGE UPS SYSTEMS Ellipse Office USB</name>
+ <value>newhidups11</value>
+ </option>
+ <option>
+ <name>MGE UPS SYSTEMS Pulsar Evolution USB</name>
+ <value>newhidups12</value>
+ </option>
+ <option>
+ <name>MGE UPS SYSTEMS Evolution USB</name>
+ <value>newhidups13</value>
+ </option>
+ <option>
+ <name>MGE UPS SYSTEMS Pulsar USB</name>
+ <value>newhidups14</value>
+ </option>
+ <option>
+ <name>MicroDowell B.Box BP</name>
+ <value>cpsups00</value>
+ </option>
+ <option>
+ <name>Microsol Solis</name>
+ <value>solis00</value>
+ </option>
+ <option>
+ <name>Microsol Rhino</name>
+ <value>rhino00</value>
+ </option>
+ <option>
+ <name>Mustek Various</name>
+ <value>megatec00</value>
+ </option>
+ <option>
+ <name>Mustek Powermust</name>
+ <value>megatec01</value>
+ </option>
+ <option>
+ <name>Mustek Powermust USB</name>
+ <value>megatec02</value>
+ </option>
+ <option>
+ <name>Powercom SMK</name>
+ <value>megatec03</value>
+ </option>
+ <option>
+ <name>Powercom ULT</name>
+ <value>megatec04</value>
+ </option>
+ <option>
+ <name>Powercom Trust</name>
+ <value>powercom01</value>
+ </option>
+ <option>
+ <name>Powercom Various</name>
+ <value>powercom02</value>
+ </option>
+ <option>
+ <name>Tripp-Lite SmartUPS</name>
+ <value>tripplite00</value>
+ </option>
+ <option>
+ <name>Tripp-Lite SmartOnline</name>
+ <value>tripplitesu00</value>
+ </option>
+ <option>
+ <name>Tripp-Lite AVR USB</name>
+ <value>newhidups15</value>
+ </option>
+ <option>
+ <name>Tripp-Lite OMNI USB</name>
+ <value>newhidups16</value>
+ </option>
+ <option>
+ <name>Tripp-Lite OMNIVUS USB</name>
+ <value>tripplite_usb00</value>
+ </option>
+ <option>
+ <name>Tripp-Lite SMART USB</name>
+ <value>tripplite_usb01</value>
+ </option>
+ </options>
+ </field>
+ <field>
+ <fielddescr>&lt;strong&gt;Local UPS Port&lt;/strong&gt;</fielddescr>
+ <fieldname>port</fieldname>
+ <type>select</type>
+ <options>
+ <option>
+ <name>auto (USB only)</name>
+ <value>auto</value>
+ </option>
+ </options>
+ </field>
+ <field>
+ <fielddescr>Local UPS Generic Type</fielddescr>
+ <fieldname>upstype</fieldname>
+ <type>select</type>
+ <options>
+ <option>
+ <name></name>
+ <value></value>
+ </option>
+ <option>
+ <name>1 (APC Back-UPS using 940-0095A/C cables)</name>
+ <value>1 00</value>
+ </option>
+ <option>
+ <name>2 (APC Back-UPS using 940-0020B/C cables)</name>
+ <value>2 00</value>
+ </option>
+ <option>
+ <name>9 (APC Back-UPS using 940-0023A cable)</name>
+ <value>9 00</value>
+ </option>
+ <option>
+ <name>12 (APC Back-UPS Office using 940-0119A cable)</name>
+ <value>12 00</value>
+ </option>
+ <option>
+ <name>12 (APC Masterswitch using 940-0020 cable)</name>
+ <value>12 01</value>
+ </option>
+ <option>
+ <name>20 (APC Back-UPS RS)</name>
+ <value>20 00</value>
+ </option>
+ <option>
+ <name>6 (Best Power Patriot using INT51 cable)</name>
+ <value>6 00</value>
+ </option>
+ </options>
+ </field>
+ <field>
+ <fielddescr>Local UPS Cable Type</fielddescr>
+ <fieldname>cable</fieldname>
+ <type>select</type>
+ <options>
+ <option>
+ <name></name>
+ <value></value>
+ </option>
+ <option>
+ <name>940-0095B (Gray Cable)</name>
+ <value>940-0095B 00</value>
+ </option>
+ <option>
+ <name>940-0024C (Black Cable)</name>
+ <value>940-0024C 00</value>
+ </option>
+ </options>
+ </field>
+ <field>
+ <fielddescr>Local Remote Access Address &lt;br&gt;(ex: 192.168.1.0/24)</fielddescr>
+ <fieldname>allowaddr</fieldname>
+ <type>input</type>
+ </field>
+ <field>
+ <fielddescr>Local Remote Access User</fielddescr>
+ <fieldname>allowuser</fieldname>
+ <type>input</type>
+ </field>
+ <field>
+ <fielddescr>Local Remote Acces Password</fielddescr>
+ <fieldname>allowpass</fieldname>
+ <type>password</type>
+ </field>
+ <field>
+ <fielddescr>&lt;strong&gt;Remote UPS Name&lt;/strong&gt;</fielddescr>
+ <fieldname>remotename</fieldname>
+ <type>input</type>
+ </field>
+ <field>
+ <fielddescr>&lt;strong&gt;Remote UPS Address&lt;/strong&gt; &lt;br&gt;(ex: 192.168.1.10)</fielddescr>
+ <fieldname>remoteaddr</fieldname>
+ <type>input</type>
+ </field>
+ <field>
+ <fielddescr>&lt;strong&gt;Remote UPS User&lt;/strong&gt;</fielddescr>
+ <fieldname>remoteuser</fieldname>
+ <type>input</type>
+ </field>
+ <field>
+ <fielddescr>&lt;strong&gt;Remote UPS Password&lt;/strong&gt;</fielddescr>
+ <fieldname>remotepass</fieldname>
+ <type>password</type>
+ </field>
+ </fields>
+ <custom_php_command_before_form>
+ before_form_nut(&amp;$pkg);
+ </custom_php_command_before_form>
+ <custom_php_validation_command>
+ validate_form_nut($_POST, &amp;$input_errors);
+ </custom_php_validation_command>
+ <custom_php_resync_config_command>
+ sync_package_nut();
+ </custom_php_resync_config_command>
+ <custom_php_deinstall_command>
+ deinstall_package_nut();
+ </custom_php_deinstall_command>
+</packagegui>
diff --git a/config/nut/status_nut.php b/config/nut/status_nut.php
new file mode 100644
index 00000000..a181734f
--- /dev/null
+++ b/config/nut/status_nut.php
@@ -0,0 +1,242 @@
+<?php
+/*
+ status_nut.php
+ part of pfSense (http://www.pfsense.com/)
+
+ Copyright (C) 2007 Ryan Wagoner <rswagoner@gmail.com>.
+ All rights reserved.
+
+ Redistribution and use in source and binary forms, with or without
+ modification, are permitted provided that the following conditions are met:
+
+ 1. Redistributions of source code must retain the above copyright notice,
+ this list of conditions and the following disclaimer.
+
+ 2. Redistributions in binary form must reproduce the above copyright
+ notice, this list of conditions and the following disclaimer in the
+ documentation and/or other materials provided with the distribution.
+
+ THIS SOFTWARE IS PROVIDED ``AS IS'' AND ANY EXPRESS OR IMPLIED WARRANTIES,
+ INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY
+ AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE
+ AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY,
+ OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
+ SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
+ INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
+ CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
+ ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
+ POSSIBILITY OF SUCH DAMAGE.
+*/
+
+require("guiconfig.inc");
+
+$nut_config = $config['installedpackages']['nut']['config'][0];
+
+/* functions */
+
+function tblopen () {
+ print('<table width="100%" class="tabcont" cellspacing="0" cellpadding="6">'."\n");
+}
+
+function tblclose () {
+ print("</table>\n");
+}
+
+function tblrow ($name, $value, $symbol = null) {
+ if(!$value) return;
+
+ if($symbol == '&deg;')
+ $value = sprintf("%.1f", $value);
+
+ if($symbol == 'Hz')
+ $value = sprintf("%d", $value);
+
+ print(<<<EOD
+<tr>
+ <td class="vncellreq" width="100px">{$name}</td>
+ <td class="vtable">{$value}{$symbol}</td>
+<tr>
+EOD
+ ."\n");
+}
+
+function tblrowbar ($name, $value, $symbol, $red, $yellow, $green) {
+ if(!$value) return;
+
+ $value = sprintf("%.1f", $value);
+
+ $red = explode('-', $red);
+ $yellow = explode('-', $yellow);
+ $green = explode('-', $green);
+
+ sort($red);
+ sort($yellow);
+ sort($green);
+
+ if($value >= $red[0] && $value <= ($red[0]+9)) {
+ $color = 'black';
+ $bgcolor = 'red';
+ }
+ if($value >= ($red[0]+10) && $value <= $red[1]) {
+ $color = 'white';
+ $bgcolor = 'red';
+ }
+ if($value >= $yellow[0] && $value <= $yellow[1]) {
+ $color = 'black';
+ $bgcolor = 'yellow';
+ }
+ if($value >= $green[0] && $value <= ($green[0]+9)) {
+ $color = 'black';
+ $bgcolor = 'green';
+ }
+ if($value >= ($green[0]+10) && $value <= $green[1]) {
+ $color = 'white';
+ $bgcolor = 'green';
+ }
+
+ print(<<<EOD
+<tr>
+ <td class="vncellreq" width="100px">{$name}</td>
+ <td class="vtable">
+ <div style="width: 125px; height: 12px; border-top: thin solid gray; border-bottom: thin solid gray;">
+ <div style="width: {$value}{$symbol}; height: 12px; background-color: {$bgcolor};">
+ <div style="text-align: center; color: {$color}">{$value}{$symbol}</div>
+ </div>
+ </div>
+ </td>
+<tr>
+EOD
+ ."\n");
+}
+
+/* defaults to this page but if no settings are present, redirect to setup page */
+if(!$nut_config['monitor'])
+ Header("Location: /pkg_edit.php?xml=nut.xml&id=0");
+
+$pgtitle = "Status: NUT Status";
+include("head.inc");
+/* put your custom HTML head content here */
+/* using some of the $pfSenseHead function calls */
+//$pfSenseHead->addMeta("<meta http-equiv=\"refresh\" content=\"120;url={$_SERVER['SCRIPT_NAME']}\" />");
+//echo $pfSenseHead->getHTML();
+
+?>
+<body link="#0000CC" vlink="#0000CC" alink="#0000CC">
+<?php include("fbegin.inc"); ?>
+<p class="pgtitle"><?=$pgtitle?></font></p>
+<?php if ($savemsg) print_info_box($savemsg); ?>
+
+<div id="mainlevel">
+<table width="100%" border="0" cellpadding="0" cellspacing="0">
+<?php
+ $tab_array = array();
+ $tab_array[] = array(gettext("NUT Status "), true, "/status_nut.php");
+ $tab_array[] = array(gettext("NUT Settings "), false, "/pkg_edit.php?xml=nut.xml&id=0");
+ display_top_tabs($tab_array);
+?>
+</table>
+<table width="100%" border="0" cellpadding="0" cellspacing="0">
+ <tr>
+ <td>
+<?php
+ tblopen();
+
+ $running = ((int)exec('pgrep upsmon | wc -l') > 0) ? true : false;
+
+ if($nut_config['monitor'] == 'local') {
+ tblrow('Monitoring:','Local UPS');
+ $cmd = "upsc {$nut_config['name']}@localhost";
+ } else {
+ tblrow('Monitoring:','Remote UPS');
+ $cmd = "upsc {$nut_config['remotename']}@{$nut_config['remoteaddr']}";
+ }
+
+ if($running)
+ $handle = popen($cmd, 'r');
+ else
+ tblrow('ERROR:','NUT is enabled, however the service is not running!');
+
+ if($handle) {
+ $read = fread($handle, 4096);
+ pclose($handle);
+
+ $lines = explode("\n", $read);
+ $ups = array();
+ foreach($lines as $line) {
+ $line = explode(':', $line);
+ $ups[$line[0]] = trim($line[1]);
+ }
+
+ if(count($lines) == 1)
+ tblrow('ERROR:', 'Data stale!');
+
+ tblrow('Model:', $ups['ups.model']);
+
+ $status = explode(' ', $ups['ups.status']);
+ foreach($status as $condition) {
+ if($disp_status) $disp_status .= ', ';
+ switch ($condition) {
+ case 'WAIT':
+ $disp_status .= 'Waiting';
+ break;
+ case 'OFF':
+ $disp_status .= 'Off Line';
+ break;
+ case 'OL':
+ $disp_status .= 'On Line';
+ break;
+ case 'OB':
+ $disp_status .= 'On Battery';
+ break;
+ case 'TRIM':
+ $disp_status .= 'SmartTrim';
+ break;
+ case 'BOOST':
+ $disp_status .= 'SmartBoost';
+ break;
+ case 'OVER':
+ $disp_status .= 'Overload';
+ break;
+ case 'LB':
+ $disp_status .= 'Battery Low';
+ break;
+ case 'RB':
+ $disp_status .= 'Replace Battery';
+ break;
+ case 'CAL':
+ $disp_status .= 'Calibration';
+ break;
+ default:
+ $disp_status .= $condition;
+ break;
+ }
+ }
+ tblrow('Status:', $disp_status);
+
+ tblrowbar('Load:', $ups['ups.load'], '%', '100-80', '79-60', '59-0');
+ tblrowbar('Battery Charge:', $ups['battery.charge'], '%', '0-29' ,'30-79', '80-100');
+
+ tblclose();
+ tblopen();
+
+ tblrow('Runtime Remaining:', $ups['battery.runtime'], ' seconds');
+ tblrow('Battery Voltage:', $ups['battery.voltage'], 'V');
+ tblrow('Input Voltage:', $ups['input.voltage'], 'V');
+ tblrow('Input Frequency:', $ups['input.frequency'], 'Hz');
+ tblrow('Output Voltage:', $ups['output.voltage'], 'V');
+ tblrow('Temperature:', $ups['ups.temperature'], '&deg;');
+ }
+
+ tblclose();
+?>
+ </td>
+ </tr>
+</table>
+<?php
+ /* display upsc array */
+ /*print('<pre>'); print_r($ups); print('</pre>');*/
+?>
+</div>
+<?php include("fend.inc"); ?>
+</body>
+</html>